The door shall be set in motion when subjected to a 30 pound 133 n force.
Sliding doors considered a corridor door. Doors to individual hotel or motel units shall operate similarly except that when the bolt and unlatching operation is key operated from corridor or exterior side of the unit door large bow keys 2 inch full bow or 1 1 4 inch half bow shall be provided in lieu of lever type hardware on the corridor side. The door shall swing to a full open position when subjected to a 15. If such doors also form part of a fire or smoke compartment they should maintain those properties in the closed position. Glass doors shall comply with the following conditions.
Doors swinging into a corridor should be recessed doors for fire egress all doors used for fire egress should comply with the requirements of local building regulations. Sliding doors may be used for exit doors opening directly to the outside if an approved failsafe system is provided to open the door in case of fire. For other swinging doors as well as sliding and folding doors the door latch shall release when subjected to a 15 pound 67 n force. Thresholds at doorways shall not exceed 3 4 in 19 mm in height for exterior sliding doors or 1 2 in 13 mm for other types of doors.
Exceptions for power operated doors horizontal sliding doors and revolving doors refer to additional requirements that include provisions for egress through these doors revolving doors must collapse sliders must be able to be opened with a force perpendicular to the door commonly referred to as breakout or break away and. Once you ve settled on an area to add your sliding doors measure the height and width of the door opening. The relative deflection between the edge of a glass door and the adjacent wall shall not exceed the thickness of the wall plus 1 2 inch 12 7 mm for a drop height of 48 inches. Current accessibility standards require operable hardware for sliding doors to be exposed and usable from both sides when the sliding door is in the fully open position.
For other swinging doors as well as sliding and folding doors the door latch shall release when subjected to a 15 pound 67 n force. Interior sliding doors are commonly placed in front of closets but you can also use sliding doors as a room divider to improve privacy. Available in motorized version with opening driven by a low voltage motor and flush to wall push button panel or in manual version with flush fitting handle system. An exclusive patented system that offers an innovative and elegant solution to the classic sliding doors.
The code includes additional requirements for sliding fire doors and sliding doors that are required to be self latching such as doors in a health care corridor. The door shall swing to a full open position when subjected to a 15 pound 67 n force. Raised thresholds and floor level changes at accessible doorways shall be beveled with a slope no greater than 1 2 see 4 5 2. Try using interior sliding doors to separate your home office from the living room or even your kitchen from the dining room.